INLAND TECHNOLOGY INCORPORATED -- FS100, SKYSOL 100 -- 6850-01-381-4423
=====================  Product Identification  =====================

Product ID:FS100, SKYSOL 100
MSDS Date:08/03/1998
FSC:6850
NIIN:01-381-4423
Status Code:A
=== Responsible Party ===
Company Name:INLAND TECHNOLOGY INCORPORATED
Address:401 E 27TH STREET
City:TACOMA
State:WA
ZIP:98421
Country:US
Info Phone Num:800-552-3100
Emergency Phone Num:800-552-3100  800-255-3924
Resp. Party Other MSDS Num.:MSDS NO. 03151
CAGE:0K209
=== Contractor Identification ===
Address:401 E 27TH STREET
Box:City:TACOMA
State:WA
ZIP:98421-1203
Country:US
Phone:800-552-3100/253-383-1177
Contract Num:SP0450-01-M-ZD28
CAGE:0K209

=============  Composition/Information on Ingredients  =============

Ingred Name:C12-C13 PARAFFINIC HYDROCARBON
CAS:64742-48-9

Ingred Name:D-LIMONENE
CAS:5989-27-5
RTECS #:GW6360000

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: PRODUCT CONTACTING THE EYES MAY
    CAUSE EYE IRRITATION. LOW ORDER ACUTE ORAL AND DERMAL TOXICITY.
    CHRONIC: PROLONGED OR REPEATED EXPOSURE CAN LEAD TO MILD
    IRRITATION, DEFATTING AND DERMATITIS.
Explanation of Carcinogenicity:CARCINOGENIC INGREDIENTS: NONE.
Effects of Overexposure:EYE IRRITATION. SKIN IRRITATION, DEFATTING,
    DERMATITIS.
Medical Cond Aggravated by Exposure:MAY AGGRAVATE EXISTING DERMATITIS.

=======================  First Aid Measures  =======================

First Aid:EYES: IF EYE CONTACT OCCURS, FLUSH WITH WATER FOR AT LEAST 15
    MINUTES OR UNTIL IRRITATION SUBSIDES. IF IRRITATION PERSISTS,
    CONTACT PHYSICIAN. SKIN: IN CASE OF SKIN CONTACT, REMOVE ANY
    CONTAMINATED CL OTHING AND WASH SKIN THOROUGHLY WITH SOAP AND
    WATER. INHALATION: IF OVERCOME BY VAPOR, REMOVE FROM EXPOSED AREA
    AND CALL PHYSICIAN IMMEDIATELY. INGESTION: DO NT INDUCE VOMITING,
    CALL PHYSICIAN IMMEDIA TELY. IN ALL CASES, IF CONDITIONS PERSIST
    GET MEDICAL ATTENTION.

=====================  Fire Fighting Measures  =====================

Flash Point Method:PMCC
Flash Point:=63.3C, 146.F
Lower Limits:0.6
Upper Limits:7
Extinguishing Media:FOAM, WATER SPRAY, DRY CHEMICAL, CARBON DIOXIDE.
Fire Fighting Procedures:WEAR AIR SUPPLIED BREATHING EQUIPMENT FOR
    ENCLOSED AND CONFINED SPACES OR AS OTHERWISE NEEDED.
Unusual Fire/Explosion Hazard:NONE KNOWN.

==================  Accidental Release Measures  ==================

Spill Release Procedures:SHUT OFF AND ELIMINATE ALL IGNITABLE SOURCES.
    CONTAIN AND COLLECT MATERIAL. ABSORB RESIDUE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:USE AND STORE AWAY FROM HEAT, SPARKS,
    OPEN FLAME. KEEP CONTAINER SEALED WHEN NOT IN USE. READ AND
    UNDERSTAND ALL CAUTIONS, LABELS, AND MSDS BEFORE USING PRODUCT.
    HYGIENE PRACTICES: DO NOT HAVE FOOD OR  DRINK IN THE VICINITY.
    MINIMIZE BREATHING VAPOR OR MIST. AVOID PROLONGED OR REPEATED SKIN
    CONTACT.
Other Precautions:KEEP ALL CHEMICALS OUT OF THE REACH OF CHILDREN. WASH
    CONTAMINATED CLOTHING BEFORE REUSE.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE NORMALLY REQUIRED.
Ventilation:USE MECHANICAL DILUTION VENTILATION WHENEVER PRODUCT IS
    USED IN CONFINED SPACE, IS HEATED ABOVE AMBIENT TEMPERATURE OR IS
    AGITATED.
Protective Gloves:USE CHEMICAL REISISTANT GLOVES.
Eye Protection:USE SPLASH GOGGLES OR FACE SHIELD WHEN EYE CONTACT MAY
    OCCUR.
Other Protective Equipment:PROVIDE EYE WASH OR STERILE EYE RINSE.
Work Hygienic Practices:DO NOT HAVE FOOD OR DRINK IN THE VICINITY.
    MINIMIZE BREATHING VAPOR OR MIST. AVOID PROLONGED OR REPEATED
    CONTACT WITH SKIN. WASH CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health

==================  Physical/Chemical Properties  ==================

HCC:V4
Boiling Pt:=171.1C, 340.F
Vapor Pres:<2  MM HG @ 25C
Vapor Density:>5(AIR=1)
Spec Gravity:0.78 (H2O=1)
Evaporation Rate & Reference:<0.1(N-BUTYL ACETATE=1)
Solubility in Water:NOT WATER SOLUBLE.
Appearance and Odor:CLEAR WITH MILD CITRUS ODOR.
Percent Volatiles by Volume:100

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT WITH STRONG ACIDS AND STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CO2, CO, AND HYDROCARBONS.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

===================  Toxicological Information	===================

Toxicological Information:SKYSOL 100 HAS LOW VAPOR PRESSURE TO CONTROL
    VOC EMISSIONS. IT IS NON-CARCINOGENIC AND CONTAINS NO INGREDIENTS
    LISTED BY SARA, TITLE I I I, SECTION 302 AND 313, CERLA, AND RCRA.
    WORKER EXPOSURE IS NOT  REGULATED BY THE OSHA Z-LIST.

=====================  Ecological Information  =====================

Ecological:SKYSOL 100 WAS SPECIFICALLY DESIGNED FOR THE WEAPONS
    INDUSTRY AS A RESIDUE REMOVER AND GENERAL SOLVENT CLEANER. SKYSOL
    100 IS A STATE OF THE ART SOLVENT DESIGNED TO HELP USERS BREAK OUT
    OF THE TANGLE  OF REGULATIONS REGARDING EMISSIONS, DISPOSAL, AND
    INDUSTRIAL HEALTH HAZARDS.

====================  Disposal Considerations  ====================

Waste Disposal Methods:CONTACT FEDERAL, STATE, COUNTY, OR LOCAL
    ENVIRONMENTAL REGULATORY AGENCIES FOR GUIDANCE.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.