GARD CORPORATION -- GARD HIGH PERFORMANCE 10W-30 -- 9150-01-413-6897
===================== Product Identification =====================
Product ID:GARD HIGH PERFORMANCE 10W-30
MSDS Date:01/01/1987
FSC:9150
NIIN:01-413-6897
Status Code:A
=== Responsible Party ===
Company Name:GARD CORPORATION
Address:2727 ROE LANE
City:KANSAS CITY
State:KS
ZIP:66103
Country:US
Info Phone Num:913-236-5000
Emergency Phone Num:913-236-5000
Preparer's Name:ROBER BENTZ
CAGE:3K676
=== Contractor Identification ===
Company Name:UNIMARK OIL COMPANY (FORMERLY GARD OIL)
Address:2727 ROE LANE
City:KANSAS CITY
State:KS
ZIP:66103-1543
Country:US
Phone:913-236-5000; FX 913-236-4419
CAGE:3K676
============= Composition/Information on Ingredients =============
Ingred Name:RE-REFINED HYDROTREATED PETROLEUM LUBRICATING OIL
CAS:64742-62-7
Fraction by Wt: 50-60%
Other REC Limits:NONE RECOMMENDED
Ingred Name:SOLVENT DEWAXED RESIDUAL OIL (PETROLEUM)
CAS:64742-62-7
Fraction by Wt: 20-25%
Other REC Limits:NONE RECOMMENDED
Ingred Name:PROPRIETARY ADDITIVES IN CARRIER OIL
Fraction by Wt: 20-25%
Other REC Limits:NONE RECOMMENDED
Ingred Name:ZINC C1-C14 ALKYLDITHIOPHOSHPATE
CAS:68649-42-3
Fraction by Wt: 0-1.2%
Other REC Limits:NONE RECOMMENDED
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN:MATL AFT PROL/REP CONTACT MAY
CAUSE IRRIT DUE TO SENSITIZATION,RASH,ERMATITUS.EYE:MATL WILL CAUSE
IRRIT.INHAL:EXCESSIVE HOT VAP/OIL MIST INHAL CAN CASUE NASAL/RESP
IRRIT.INGEST:SYMPTOMS SIMILAR T O INHAL W/ADDN HEALTH CONCERNS SUCH
AS CHEM PNEUMONITIS(ASPIRATION OF CHEM INTO LUNGS).HAS LAXATIVE
PROPERTIES (SUPPLEM)
Explanation of Carcinogenicity:PER MSDS:USED MOTOR OIL HAS BEEN SHOWN
TO CAUSE SKIN CANC IN CERTAIN LAB ANIMALS CONT EXPO TO USED MOTOR
OIL BY REP APPL
Effects of Overexposure:SKIN IRRIT DUE TO SENSITIZATION,RASH,ERMATITUS.
EYE IRRIT. NASAL/RESPIRATORY IRRIT. CHEMICAL PNEUMONITIS, LAXATIVE
PROPERTIES,NAUSEA,ABDOMINAL CRAMPS,DIARRHEA.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:EYE/SKIN:IMMED FLUSH EYE W/LG AMT OF WATER FOR @LEAST
15MINS.WASH SKIN AREAS WELL W/SOAP/WATER.REMOVE EXPO CLOTH.IRRIT
PERSIST CONSULT PHYSICIAN.INHAL:REMOVE TO FRESH AIR.NOT BREATH GIVE
ART RESP.DIFF BREATH ADMINISTER OXY.GET PROMPT MED ATTN.INGEST:DO
NOT INDUCE VOMIT.KEEP WARM/QUIET.NEVER GIVE ANYTHING BY MOUTH TO
DROWSY/UNCONSC PERSON.GET IMMED MED ATTN.
===================== Fire Fighting Measures =====================
Flash Point Method:COC
Flash Point:392F,200C
Autoignition Temp:Autoignition Temp Text:NP
Lower Limits:N/DETERMINED
Upper Limits:N/DETERMINED
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, POLYMER FOAM, WATER
FOG.
Fire Fighting Procedures:ADDN OF WATER TO BURNING MATL WILL REDUCE
INTENSITY OF FLAME BUT SPREAD FIRE.FIREFIGHTERS SHOULD BE EQUIPPED
W/APPROPRIATE PROT GEAR,USE MSHA/NIOSH APPROVE(SUP)
Unusual Fire/Explosion Hazard:CNTNR DEVELOP PRESSURE WHEN HEATED;MAY
RUPTURE DURING FIRE CAUSING POT EXPLO SITUATION.KEEP SEAL CNTNR
COLL W/WATERSPRAY.CNTNR SUED FOR STORAGE MAY RETAIN(SUPP)
================== Accidental Release Measures ==================
Spill Release Procedures:USE PPE.IMMED TURN OFF/ISOLATE IGN
SOURCES.EVACUATE AREA/VENTI.PERSONNEL W/PROPER PPE SHOULD CONTAIN
SPILL IMMED W/INERT MATLS(SAND,EARTH,CHEM SPILL PADS OF
COTTON)W/DIKES IN MANNER THAT KEEP SPILL AW AY FROM
SEWERS/WATERWAYS.LG:CONTAIN.PICKUP(SUPP)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:DON'T TRANSFER TO UNMARKED
CNTNRS.STORE IN CLSD CNTNRS AWAY FROM HEAT/SPARKS/OPEN
FLAME/OXIDIZING MATLS.PROD CLASSIFIED AS COMBUST UNDER DOT REGS.
Other Precautions:FIRE EXTINGUISHERS SHOULD BE KEPT READILY
AVAILABLE.SEE NFPA 30 & OSHA 1910.106-FLAMM/COMBUSTIBLE LIQS.AVOID
PROL/REP CONTACT TO SKIN.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE REQUIRE IF AIRBORNE CONCEN MAINTAIN BEL
THRESHHOLD LIMITS.OTHERWISE RESPIRATORY PROTECTION PROGRAM MEETING
OSHA 1910.134/ANSI Z88.2 REMQTS MUST BE FOLLOWED.MISTING-WEAR
MSHA/NIOSH APPROV/EQUIVA 1 /2MASK FORM DUST/MIST AIR PURI RESPIRATR
Ventilation:USE ADQU VENTI WHEN WORK W/MATL IN ENCLSD AREA.MECH
METHODS(FUME HOODS,AREA FANS)USE TO RED LOC VAP/MIST AREA.
Protective Gloves:SOLVT IMPERV-VINYL,PLAST,NITRIL,BUTYL RB
Eye Protection:SAF GLASSES W/SIDESHIELD,VENT GOGG.
Other Protective Equipment:EYEWASH STATIONS,SHOWERS SHOULD BE AVAI IN
AREA WHERE MATL USED/STORED.EYE WARE:ANSI Z87.1 OR APPROVE EQUIV.
Work Hygienic Practices:LAUNDER EXPO CLOTH BEF REUSE.
Supplemental Safety and Health
FIREFIGHTER:BREATH MASK(PRESSURE DEMAND/EQUIVAL). FIRE/EXPLO
HAZ:COMBUST/FLAMM VAP.AVOID HEAT/WELD/CUT/ETC OF EMPTY DR-AVOIDS
POSSIBILITY OF IGN RESIDUE.RETURN DR TO PROPER COLLECTION SITES FOR
DISPO/ RECYC. HEALTH:MAY CAUSE NAU,ABD CRAMPS,DIARR. SPILL:W/EXPLO
PROOF/NONSPARK VAC PUMPS/SHOVEL/ETC & NOTIFY AUTHORITIES.
================== Physical/Chemical Properties ==================
HCC:V6
Boiling Pt:B.P. Text:>500F,>260C
Melt/Freeze Pt:M.P/F.P Text:NP
Decomp Temp:Decomp Text:NP
Vapor Pres:<0.1MM
Vapor Density:>1
Spec Gravity:0.88 @15.6C
pH:NP
Viscosity:NP
Evaporation Rate & Reference:N/DETERMINED.
Solubility in Water:NOT SOLUBLE.
Appearance and Odor:AMBER-BROWN FLUID W/CHARACTERISTIC PETROLEUM ODOR.
Percent Volatiles by Volume:<1
Corrosion Rate:NP
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:THERM DECOMP YIELD OXIDES OF
CARBON,NIROGEN,SUFLUR,PHOSPHORUS,ZN,CA,MAGNESIUM,SODIUM.NOXIOUS
SMOKE MAY ALSO DEVELOPE.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF IAW ALL LOCAL, STATE AND FEDERAL
REGULATIONS.CERCLA HAZ SUBSTANCE/TOXIC CHEM:YES.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.