TELEDYNE STERLING HUNT -- SCOURING POWDER -- 7930-00N050188
=====================  Product Identification  =====================

Product ID:SCOURING POWDER
MSDS Date:12/01/1985
FSC:7930
NIIN:00N050188
=== Responsible Party ===
Company Name:TELEDYNE STERLING HUNT
Box:157
City:SOUTH DARTMOUTH
State:MA
ZIP:02748
Country:US
Info Phone Num:617-999-4446
Emergency Phone Num:617-999-4446
CAGE:TELSH
=== Contractor Identification ===
Company Name:TELEDYNE STERLING HUNT
Box:City:SOUTH DARTMOUTH
State:MA
ZIP:02748
Country:US
Phone:617-999-4446
CAGE:TELSH

=============  Composition/Information on Ingredients  =============

Ingred Name:SILICON DIOXIDE, AMORPHOUS; (SILICON DIOXIDE POWDER)
CAS:112945-52-5
RTECS #:VV7310000
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:CHLORINE; (CHLORINE CONTAINING BLEACH)  (SARA III)
CAS:7782-50-5
RTECS #:FO2100000
Fraction by Wt: <1%
OSHA PEL:1 PPM, C
ACGIH TLV:0.5 PPM;1 STEL
EPA Rpt Qty:10 LBS
DOT Rpt Qty:10 LBS

Ingred Name:SURFACTANT (TYPE NOT SPECIFIED); (VARIOUS NON-HAZARDOUS
    SURFACTANT MATERIALS)
Fraction by Wt: <2%
OSHA PEL:N/K 
ACGIH TLV:N/K 

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO	Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:WITHIN THE MEANING OF FEDERAL
    HAZARDOUS SUBSTANCE LABELING ACT, THIS PRODUCT IS NOT TOXIC ORALLY,
    IS NOT IRRITATING TO THE SKIN & IS AN EYE IRRITANT. CARELESS USAGE,
    OTHER THAN AS PER DIRECTIONS, MAY  PRODUCE POTENTIALLY
    EYE-IRRITATING DUST.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INGEST:CALL MD IMMEDIATELY . INHAL:REMOVE TO FRESH AIR.
    SUPPORT BREATHING (GIVE O*2/ARTF RESP) . SKIN:FLUSH W/COPIOUS
    AMOUNTS OF WATER. CALL MD . EYE:FLUSH WELL W/RUNNING WATER FOR A T
    LEAST 15 MINUTES; GET MEDICAL ATTENTION.

=====================  Fire Fighting Measures  =====================

Flash Point:NONE
Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
    EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

==================  Accidental Release Measures  ==================

Spill Release Procedures:NORMAL CLEAN-UP.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN A COOL, DRY AREA.
Other Precautions:USE GOOD HOUSEKEEPING PRACTICES TO PREVENT
    ACCUMULATIONS OF DUST, & TO KEEP AIRBORNE CONCENTRATIONS TO A
    MINIMUM.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF DUST CONDITION OCCURS, USE A NIOSH/MSHA
    APPROVED DUST MASK.
Ventilation:NORMAL NATURAL VENTILATION.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:SAFETY GOGGLES.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

==================  Physical/Chemical Properties  ==================

Spec Gravity:8
Appearance and Odor:SOLID AS SHEET & STRIP; ODORLESS.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
    REGULATIONS . REMOVAL TO DUMP.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.